0

Columns for Gas Chromatography

eBook - Performance and Selection

Erschienen am 31.03.2007, 1. Auflage 2007
136,99 €
(inkl. MwSt.)

Download

E-Book Download
Bibliografische Daten
ISBN/EAN: 9780470114179
Sprache: Englisch
Umfang: 312 S., 13.74 MB
E-Book
Format: PDF
DRM: Adobe DRM

Beschreibung

Choosing the right column is key in Gas Chromatography

Gas Chromatography (GC) is the most widely used method for separating and analyzing a wide variety of organic compounds and gases. There have been many recent advancements in both packed column and capillary column GC. With numerous options and considerations, selecting the right column can be complicated. This resource provides essential guidance for scientists and technicians, including:

Methods of choosing both capillary and packed columnsSelection of dimensions (column length, I.D., film thickness, etc.) and type of columnGuidelines for proper connections of the column to the injector and detectorUnited States Pharmacopeia and National Formulary chromatographic methodsASTM, EPA, NIOSH, and OSHA column selection specificationsInformation on the advantages of computer assistance in GC and multidimensional GCComprehensive information on column oven temperature control

Columns for Gas Chromatography: Performance and Selection is a hands-on reference for scientists and technicians using GC.

Autorenportrait

Eugene F. Barry, PHD, is Professor of Chemistry and Head of the Chemistry Department at the University of Massachusetts Lowell and a recipient of the school's Most Outstanding Teacher Award. He is coeditor ofModern Practice of Gas Chromatography, Fourth Edition (Wiley), the standard reference for the industry. Dr. Barry is author or coauthor of over 100 publications and has several patents.

The lateRobert L. Grob, PHD, was Professor Emeritus of Analytical Chemistry at Villanova University and a consultant in analytical and environmental chemistry. He coauthoredEnvironmental Problem-Solving Using Gas and Liquid Chromatography and authoredChromatographic Analysis of the Environment, now in its third edition. Dr. Grob published over 250 research publications and held one patent. He was the recipient of the Stephen Dal Nogare Award in Chromatography, the EAS Award in Separation Science, and numerous other awards.

Inhalt

Preface.

Acknowledgments.

1 Introduction.

1.1 Evolution of Gas Chromatographic Columns.

1.2 Central Role Played by the Column.

1.3 Justification for Column Selection and Care.

1.4 Literature on Gas Chromatographic Columns.

1.5 Gas Chromatographic Resources on the Internet.

References.

2 Packed Column Gas Chromatography.

2.1 Introduction.

2.2 Solid Supports and Adsorbents.

Supports for GasLiquid Chromatography.

Adsorbents for GasSolid Chromatography.

2.3 Stationary Phases.

Requirements of a Stationary Phase.

USP Designation of Stationary Phases.

Kovats Retention Index.

McReynolds and Rohrschneider Classifications of Stationary Phases.

Evaluation of Column Operation.

Optimization of Packed Column Separations.

2.4 Column Preparation.

Coating Methods.

Tubing Materials and Dimensions.

Glass Wool Plugs and Column Fittings.

Filling the Column.

Conditioning the Column and Column Care.

2.5United States Pharmacopeia andNational Formulary Chromatographic Methods.

References.

3 Capillary Column Gas Chromatography.

3.1 Introduction.

Significance and Impact of Capillary Gas Chromatography.

Chronology of Achievements in Capillary Gas Chromatography.

Comparison of Packed and Capillary Columns.

3.2 Capillary Column Technology.

Capillary Column Materials.

Fused Silica and Other Glasses.

Extrusion of a Fused-Silica Capillary Column.

Aluminum-Clad Fused-Silica Capillary Columns.

Fused-Silica-Lined Stainless Steel Capillary Columns.

3.3 Preparation of Fused-Silica Capillary Columns.

Silanol Deactivation Procedures.

Static Coating of Capillary Columns.

Capillary Cages.

Test Mixtures for Monitoring Column Performance.

Diagnostic Role Played by Components of Test Mixtures.

3.4 Chromatographic Performance of Capillary Columns.

Golay Equation Versus the van Deemter Expression.

Choice of Carrier Gas.

Measurement of Linear Velocity and Flow Rate.

Effect of Carrier Gas Viscosity on Linear Velocity.

Phase Ratio.

Coating Efficiency.

3.5 Stationary-Phase Selection for Capillary Gas Chromatography.

Requirements.

History.

Comparison of Columns from Manufacturers.

Polysiloxane Phases.

Polyethylene Glycol Phases.

Cross-Linked Versus Chemically Bonded Phase.

Chemical Bonding.

MS-Grade Phases Versus Polysilarylene or Polysilphenylene Phases.

Sol-Gel Stationary Phases.

PhenylpolycarboraneSiloxane Phases.

3.6 Specialty Columns.

EPA Methods.

Chiral Stationary Phases.

GasSolid Adsorption Capillary Columns: PLOT Columns.

3.7 Capillary Column Selection.

Practical Considerations of Column Diameter, Film Thickness, and Column Length.

Capillary Columns of 0.53mm i.d.: Megabore Columns.

Correlation of Column Dimensions and Film Thickness with Parameters in the Fundamental Resolution Equation.

Column Selection for Gas Chromatography by Specifications.

3.8 Column Installation and Care.

Carrier Gas Purifiers.

Ferrule Materials and Fittings.

Column Installation.

Column Conditioning.

Column Bleed.

Retention Gap and Guard Columns.

Column Fatigue and Regeneration.

3.9 Special Gas Chromatographic Techniques.

Simulated Distillation.

Multidimensional Gas Chromatography.

Computer Modeling of Stationary Phases.

References.

4 Column Oven Temperature Control.

4.1 Thermal Performance Variables and Electronic Considerations.

4.2 Advantages of Temperature Programming over Isothermal Operation.

4.3 Oven Temperature Profiles for Programmed-Temperature Gas Chromatography.

4.4 Role of Computer Assistance in Optimizing Separations in Gas Chromatography.

DryLab (LC Resources).

ProezGC (Restek Corporation).

GC-SOS (Chem SW).

4.5 Fast or High-Speed Gas Chromatography.

Selectivity Tuning.

Resistively Heated Columns and Column Jackets.

4.6 Subambient Oven Temperature Control.

References.

Selected References.

Appendix A: Guide to Selection of Packed Columns.

Appendix B: Column Selection.

Index.

Informationen zu E-Books

„E-Book“ steht für digitales Buch. Um diese Art von Büchern lesen zu können wird entweder eine spezielle Software für Computer, Tablets und Smartphones oder ein E-Book Reader benötigt. Da viele verschiedene Formate (Dateien) für E-Books existieren, gilt es dabei, einiges zu beachten.
Von uns werden digitale Bücher in drei Formaten ausgeliefert. Die Formate sind EPUB mit DRM (Digital Rights Management), EPUB ohne DRM und PDF. Bei den Formaten PDF und EPUB ohne DRM müssen Sie lediglich prüfen, ob Ihr E-Book Reader kompatibel ist. Wenn ein Format mit DRM genutzt wird, besteht zusätzlich die Notwendigkeit, dass Sie einen kostenlosen Adobe® Digital Editions Account besitzen. Wenn Sie ein E-Book, das Adobe® Digital Editions benötigt herunterladen, erhalten Sie eine ASCM-Datei, die zu Digital Editions hinzugefügt und mit Ihrem Account verknüpft werden muss. Einige E-Book Reader (zum Beispiel PocketBook Touch) unterstützen auch das direkte Eingeben der Login-Daten des Adobe Accounts – somit können diese ASCM-Dateien direkt auf das betreffende Gerät kopiert werden.
Da E-Books nur für eine begrenzte Zeit – in der Regel 6 Monate – herunterladbar sind, sollten Sie stets eine Sicherheitskopie auf einem Dauerspeicher (Festplatte, USB-Stick oder CD) vorsehen. Auch ist die Menge der Downloads auf maximal 5 begrenzt.